Fixed Gas Detection

  • Home
  • Fixed Gas Detection
Image

Fixed Gas Detection Model No. ATS - 105M

  • 128 x 64 Graphics LCD Display
  • Software solutions for Gas Analysis
  • Non-intrusive calibration
  • Programmable relays
  • Available in stainless steel
  • Available in wireless version
  • Microcontroller based embedded intelligent Monitor
  • Data Logger with RS 232 and USB Computer Interface
  • Web based data transfer through GSM/GPRS Technology
  • Detection of combustible, toxic Gases and Oxygen
  • Flame proof Junction Box Approval CCOE & CMRI

Single Point Hazardous Gas Monitor/ Alarm for ambient air

Model ATS-105M is Single Point Hazardous Gas Monitor/ Alarm for ambient air. Model ATS-105 is suitable for Combustible gases (%LEL) or PPM level of CO, H2S, SO2, NO, NO2, CL2, B2H6, Hydrocarbons, organic solvents and other Toxic Gases.

The ATS-105M features a rugged, long-life Electrochemical, Catalytic Pellister, metal oxide semiconductor (MOS) sensor. The sensor is available either in a separate junction box for remote mounting up to several hundred Meters from the monitor, or as an integral component attached to the instrument. The ATS-105M provides a Graphics LCD display of gas concentrations, audio/visual alarms, relay contacts, plus analog (4-20mA ) and digital RS 232/485 and USB outputs.

Accept Single 4-20 mA Input from Remote Sensor/Transmitter.

Multi Chanel Gas Monitor

Model ATS-107M is Multi channel gas Monitor for environmental Monitoring and Leak detection. The ATS-107M is an economical, yet versatile Multi channel controller with the features needed for monitoring a remote 4-20 mA gas sensor/transmitter or similar device. The instrument provides 24 VDC power, audio/visual alarms, alarm relays and other features. The ATS-107M is easy to install, designed for wall mounting and completely programmable from the front panel membrane switches.

Accept Multi 4-20 mA Input from Remote Sensor/Transmitter.

  • Environmental Monitoring
  • Area Monitoring
  • Leak Detection & Monitoring
  • Chemical Plants
  • Refineries/Petrochemical
  • Hazardous Area
  • Water/West water Treatment
  • Fire Services Mines
  • Mines
Principle Electrochemical, Solid State Semiconductor Catalytic and PID
Range PPM/PPB or mg/M3
Resolution 0.1 Unit or 1 Unit(Application Based)
Sampling Method Diffusion
Display 128 X 64 Graphics LCD
Alarm Relay Contact No + NC
Anolog out Put 4 - 20mA
Digital out Put S 232, RS 485 and Modbus Communication protocol
Power Source 230 V AC
Accuracy +/2%
Response Time <5 Second
Data Storage 1000 or 10000
Sensor Life 2-3 Years
Temperature 15degree Celsius
Humidity < 85%RH
Atmosphere Pressure 86 - 106Kpa
Dimension in mm 210 (W) X 180(H) X 110(D)
Weight 1.2 KG
Warranty One Year